Please use this identifier to cite or link to this item:
http://irepo.futminna.edu.ng:8080/jspui/handle/123456789/31308Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ocheni, A. U. U | - |
| dc.contributor.author | Oyedum, O. D. | - |
| dc.contributor.author | Ndubuka, N. M. | - |
| dc.contributor.author | Moses, A. S | - |
| dc.date.accessioned | 2026-05-18T22:09:25Z | - |
| dc.date.available | 2026-05-18T22:09:25Z | - |
| dc.date.issued | 2023-06-12 | - |
| dc.identifier.citation | A. U. U. Ocheni, O. D. Oyedum, N. M. Ndubuka, A. S. Moses (2023). Analysis of Magnetic Field Exposure at Extremely Low Frequency (ELF) in 330kV Transmission Switchyards. Journal of Materials Engineering, Structures and Computation 2(2) pp.12-19. https://doi.org/10.5281/zenodo.8027569 | en_US |
| dc.identifier.uri | http://irepo.futminna.edu.ng:8080/jspui/handle/123456789/31308 | - |
| dc.description.abstract | The present study assessed the exposure levels of extremely low frequency (ELF) magnetic fields in five 330 kV transmission switchyard of generation stations located in north-central, Nigeria. In conformity with IEEE standards of measurement procedures, ELF magnetic field levels were detected in the switchyards using Extech 480826 triple-axis EMF metre via spot technique at three different observation heights of 1.0, 1.5 and 1.8 m. The data obtained were subjected to analysis using the One-way ANOVA SPSS package. The results demonstrated occupational significant differences of (p < .001) between 330 kV switchyards of Shiroro Hydro-plant and Geregu Phase II Gas-plant, significant differences of (p = .045) between switchyards of Geregu Phase I Gas-plant and Geregu Phase II Gas-plant, and also significant differences of (p < .001) in occupational exposure was demonstrated between switchyards of Jebba Hydro-plant, Kainji Hydro-plant when separately compared to Geregu Phase I and Geregu Phase II Gasplants. However, non-significant differences occurred between switchyards of Shiroro Hydro-plant and Jebba Hydro-plant, Kainji Hydro-plant and Geregu Phase I Gas-plant, and Jebba Hydro-plant with Kainji Hydro-plant. This study has revealed the occurrence of field pollution within the switchyard and the variation of ELF magnetic field magnitude from between switchyards | en_US |
| dc.publisher | Journal of Materials Engineering, Structures and Computation | en_US |
| dc.subject | ELF magnetic field, Switchyards, Transmission stations, ANOVA, Electro pollution, and Occupational exposure | en_US |
| dc.title | Analysis of Magnetic Field Exposure at Extremely Low Frequency (ELF) in 330kV Transmission Switchyards | en_US |
| Appears in Collections: | Physics | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Analysis of Magnetic Field Exposure at Extremely.pdf | 351.23 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.