Please use this identifier to cite or link to this item:
http://irepo.futminna.edu.ng:8080/jspui/handle/123456789/16968
Title: | Development of a Test Rig for the Determination of Head loss and Friction Factor of a Polyvinyl Chloride (PVC) Pipes |
Authors: | Musa, N. A Jiya, J. Y. Aderoju, T. K |
Keywords: | Headloss Friction Factor PVC Pipes Test rig Water |
Issue Date: | 2016 |
Abstract: | This paper reports the design, construction and performance evaluation of a test rig for determining the head loss and friction factor of PVC pipes of different diameters (13mm, 19mm and 25mm) transporting water. On performance evaluation, friction factors of 0.0121, 0.0396 , 0.0171 and head losses of 37.8mm, 25.2mm and 12.6mm for 13mm, 19mm, and 25mm diameter PVC pipes respectively were obtained. |
URI: | http://repository.futminna.edu.ng:8080/jspui/handle/123456789/16968 |
ISSN: | 2225-0573 |
Appears in Collections: | Mechanical Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Development of a Test Rig for the Determination of Headloss and.pdf | 1.03 MB | Adobe PDF | View/Open |